Fire
Alarm System In General
Fire alarm system is an important
security device that helps to get protectecred ourselves from fire
accidents. Nowadays fire alarm system became an essential one
because of fire accidents. fire alarm system rises a loud sound
and alerts , as soon as smoke is deducted by the smoke detector. In most
cases fire alarm systems act at the instigation of fire detectors
and other devices.
The Fire alert is of two types
1. Fire alarm System
2. Fire Suppression System
The Fire alarm is of two types
1. Addressable Fire alarm System
2. Conventional Fire Alarm System
Addressable Fire
Alarm System
This
type of fire alarm system addressable fire panel is more advanced
than a fire alarm system conventional panel. There are more programming
options with these devices and as single point detection is an added option
in this fire alarm system addressable pannel, it is easy to discover
where an alarm device went off in the building using fire alarm system
addressable fire panel and what alarm device is signalling a problem
all those stuffs are shown in the display of fire alarm system addressable
fire panel. An addressable fire alarm panel usually has loops
and each loop corresponds with a number of alarm devices.The panel which
shows the exact place of fire is called addressable fire alarm
panel. In this fire alarm system addressable fire panel diffrent
places are classified into loops. Per loop around 250 detectors are connected
. Basic thing which are required In addressable fire alarm are
addressable fire panel , addressable fire alarm smoke detector
, fire alarm MCP (mannual Call Point ) , fire alarm
Hooter ( sounder ). Important point is that the addressable detector will
no support conventional panel and vice versa
Conventional Fire
Alarm System
Conventional
fire alarm system fire panels have a small circuits connected
to the device. The circuit covering the are a under protection are called
as zone in the building in Conventional fire alarm system.
LED lights indicates if an area or zone in a building has been activated
in the fire alarm system fire panels.The fire alarm
device does not show the exact locatiom of fire. Conventional fire
alarm panel shows only the approximate place of fire. Per zone 20
to 30 devices can be connected. Basic thing which are required In Conventional
fire alarm are addressable fire panel , Conventional fire alarm
smoke detector , Conventional fire alarm MCP (mannual Call Point
) ,Conventional fire alarm Hooter ( sounder ). Important point
is that the Conventional detector will no support conventional panel and
vice versa.
fire alarm system Control
Units
The fire alarm system is controlled
by a fire alarm control panel. Like any other security devices
this fire alarm control panel can be referred as the head or
brain of the fire alarm signal device. To priorly approximately
how many fire alarm fire detector should operate shold be calculated.
Besides this there are two more important units. The fire alarm
signal that performs the main function and fire alarm pull station
which transmits signals to the fire alarm through pull boxes.
Fire Alarm System
Detectors
There are three types of fire alarm
system detector
1.Fire alarm system smoke detector
- when smoke comes , it senses it and then it sends to panel
2.Fire alarm system heat detector -when room temperature exceeds
certain limt , it senses it and then it sends to panel.
It is used in kitchen ,pantry etc . where smoke is normally prevelant
3.Fire alarm system Photo detector - Whenever spark comes in
the electrical cable the signal will be sent to panel
NOTE*- Multi sensor is also avilable which
detecs all the above.
Ionization detector is banned in india.
Fire Alarm System
Smoke Detectors
Fire alarm system Smoke detectors
can further be divided into two categories namely Fire alarm
ionization smoke detectors and Fire alarm photo electronic
ionization units. A Fire alarm smoke detector will be
helpful to deduct fire even before a fire catches. A Fire alarm smoke
detector will therefore be able to help you in taking preventive
actions at an early stage. Fire alarm Photo electronic ionization
detectors can be used in houses while the other category can be used in
offices. But the Photo electronic ionizationis banned in
Fire Alarm System
Heat Detectors
Fire Alarm System heat detectors
come in two types. They are known as fixed temperature and rate of rise
Fire Alarm System heat detectors. In the first type the device
will work if the room temperature reaches an optimal level of 45 °C
or 60° C. However they can very well sense sudden and upward fluctuations
of temperature. This device has a limitation when compared with smoke
detectors because heat detectors can only recognize high levels of temperature
and it is difficult to save property or people in most cases.This type
Fire alarm system detectors are used in kitchen and in Ups rooms etc
Fire Alarm System Sounding devices
Alarm signal devices are of two categories namely audible
and visual. The first one Emits loud noise and alerts you to escape from
the fire outbreak. The loud noise may be in the form of bells or speakers
or even sirens. Similarly visuals catch your attention by emitting certain
types of lights like strobe light. It is also possible to intimate the
fire service personnel through the sound.
Fire Suppression
incase of over all building height is more
than 15m as per , National building Code it is compulsary to install sprinkler
system
Sprinkler system
The sprinkler consist of a thin bulb with
a liquid in it, it gets burst when the temperature xceeds 68 degree
Gas Based Fire Suppression
In order to protect the server room and
data centres where the sprinkler system fails the gas based fire suppression
is used
|